Case Study | Proactively Identifying Bearing Electrical Erosion Risks to Prevent Unplanned Shutdowns of Cement Kiln Head Fans!
Release time:2026-11-05
On a cement production line, the kiln-head cooling fan is a core piece of equipment that safeguards the thermal balance at the kiln head. If it fails, the entire production line will be disrupted.
Among them Electrical erosion of bearings It is a highly insidious equipment killer. In the early stages of failure, it manifests only as deteriorating lubrication, making it easy for on-site personnel to overlook. If shaft current is allowed to persist and continue breaking down the lubricant film, the bearing raceways will be burned, developing scuffing marks; in severe cases, this leads directly to bearing seizure, causing sudden wind turbine shutdowns and resulting in significant production losses for the enterprise.
Recently, the kiln-head cooling fan of a major cement company leveraged Zhongyun Technology’s intelligent operations and maintenance platform to deliver a progressive fault‑prevention alert. Starting with early signs of lubricant degradation and progressing to the identification of bearing electrical erosion risks, the system enabled planned maintenance, successfully averting a major equipment hazard.
I. The signal rises slowly, and lubricant degradation quietly sets in.
Since September 16, 2026, the intelligent operations and maintenance platform has detected a sustained, gradual increase in the RMS values of vibration acceleration and velocity at the free-end measurement point of this cooling fan.
As of October 22, the acceleration values had doubled compared to the initial stage of the fault, the vibration waveforms exhibited impact characteristics, and the high-frequency background noise rose in tandem. Based on comprehensive trend analysis and spectral diagnostics, the platform promptly issued an early warning: the equipment is experiencing Hidden Risks of Lubricant Deterioration , reminding on-site personnel to promptly verify the equipment status.
II. Data Deteriorating Rapidly! Diagnosis Upgraded to Pinpoint Bearing Electrical Erosion
On the evening of October 26, the equipment’s condition deteriorated sharply, with vibration metrics showing a precipitous decline: the peak acceleration surged to 33.58 m/s², and the vibration velocity reached as high as 108.44 mm/s, triggering a threshold alarm on the platform.
The diagnostic team, by analyzing vibration waveforms and spectral characteristics, determined that the root cause of the fault is Electrical erosion of bearings — Axial current causes dielectric breakdown of the oil film, leading to discharge and progressive damage to the bearing raceway. The platform promptly updated the diagnostic conclusion, upgrading the assessment from “lubrication degradation” to a risk of electrical erosion damage to the bearing, and urgently recommended immediate shutdown for inspection and corrective action.
3. Shutdown, disassembly, inspection, and verification! Checkboard pattern verification platform diagnostics
Following the platform’s operations and maintenance recommendations, the company scheduled a shutdown on October 29 for an open‑cover inspection.
The on-site disassembly and inspection results closely matched the platform diagnostics: significant oil leakage was observed at both ends of the fan bearing, the bearing body itself showed signs of burning, and characteristic scuffing patterns indicative of electrical erosion were visible on the journal.
Bearing maintenance and damage repair were promptly carried out on site. After the equipment was returned to service, platform monitoring data normalized: free-end vibration acceleration stabilized, abnormal impact signals disappeared entirely, high-frequency noise improved markedly, and the fan resumed healthy operation.
IV. Post-Mortem Analysis: Seizing the Precious Window of Opportunity to Intervene in the Incident
Bearing electrical erosion failures follow a clear progression: lubrication degradation → electrical erosion damage → complete bearing burnout and seizure. Before total failure occurs, this leaves operations and maintenance personnel with a valuable window for intervention. This successful resolution offers three key operational insights:
1. Closely monitor trend changes, rather than focusing solely on instantaneous values.
The platform fully records the entire equipment degradation process from September 16 to October 26, reconstructing the evolution from gradual deterioration to rapid failure. This provides a solid basis for tiered fault diagnosis and eliminates misjudgments caused by single-point alarms.
2. In-depth graph analysis to distinguish fault types
Electrical erosion faults generate characteristic 50 Hz periodic waveforms and their harmonics, which is the key distinction from ordinary bearing wear. The platform did not stop at a simple diagnosis of inadequate lubrication; it completed fault escalation identification on the very night of the data anomaly.
3. Implement proactive early intervention to prevent severe shutdown incidents.
From detecting early warning signs to implementing shutdowns for maintenance, intelligent early warning systems provide ample time for on-site response. Repairs are completed before catastrophic bearing failure occurs, thereby avoiding the production risks associated with cascading shutdowns of the kiln head system.
Zhongyun Technology continues to deepen its expertise in industrial intelligent operations and maintenance, providing fault early warning and intelligent diagnostic services for critical equipment in industries such as cement and building materials, helping enterprises shift from “reactive repair” to “predictive maintenance.”